Back to list

Tech Blog · Prescriptive AI

Why is APC found only in large companies' plants?

Advanced process control (APC) is a proven technology, but most of its applications are concentrated in refining and petrochemicals. We break down where its adoption costs come from and what data-driven prescription needs in order to fill the gap.

Jul 7, 2026 · OPTI-X

Advanced process control (APC) has long been used in large continuous processes such as oil refining, petrochemicals and power generation. Its core algorithm, model predictive control (MPC), was originally developed to meet the control needs of power plants and refineries. It is a proven technology, so why is it seen only in large plants?

Where APC is used

Qin et al. (2003) surveyed the major MPC vendors and tallied applications by area. As of mid-1999, there were about 4,542 linear MPC applications. Among applications with a known area, refining accounted for 67%, and adding petrochemicals brings it to 2,535 of 2,941 applications in refining and petrochemicals.

Linear MPC applications by area

Vendor survey estimates, mid-1999 · excludes 1,601 unclassified applications

Refining
1,985 applications
Petrochemicals
550 applications
Chemicals
144 applications
Pulp and paper
68 applications
Food processing
51 applications
Furnaces
45 applications
Mining and metallurgy
37 applications
Five other areas
61 applications
Source: Qin et al. (2003), reconstructed from Table 6

The authors named chemicals, pulp and paper, food processing, aerospace and automotive as growth areas. Even so, by count, refining alone had more applications than all the other areas combined. The authors add that a single application can range from one variable to several hundred, so the counts should not be read as market share.

Most of the cost is "people and time"

MPC uses a process model to calculate how the process will move. This model is mostly built from plant test data — a test that changes manipulated variables in steps and records how the process responds.

The APC adoption process

Each stage takes experienced engineers and production time

01Pre-testMoving manipulated variables to check instruments and PID loops, measuring time to steady state
02Plant test8–15 steps per variable, up to 5–15 days of round-the-clock monitoring
03Model identification and tuningEstimating a dynamic model from test data and configuring the controller
04MaintenanceRebuilding the model when PID tuning or the process changes significantly
Source: Compiled from Qin et al. (2003)

According to Qin et al., a plant test runs 24 hours a day with engineers monitoring it. Each manipulated variable is stepped 8 to 15 times, and depending on the number of variables and the time to steady state, the test can take up to 5–15 days. PID tuning cannot be changed during the test, and operators intervene only in critical situations.

The authors also point out limitations. There is no tool to judge whether the collected data are adequate, so plants tend to be over-tested in practice, which increases the build cost. Methods to verify whether a model has deteriorated after commissioning were also lacking.

Same technology, different math

The economic benefit of APC comes less from reducing variation itself than from moving the setpoint closer to a constraint by as much as the variation has been reduced. Richalet et al., cited by Qin et al., divide plant control into four layers — scheduling, setpoint optimization, multivariable dynamic control and valve PID — and explain that the real benefit arises in the setpoint optimization layer.

When the fluctuation in reactor temperature shrinks, the setpoint can be pushed toward the limit without crossing the quality limit. This benefit scales with throughput, so it grows with equipment size. By contrast, the people and time needed for testing and model building do not shrink as much when the equipment is smaller. That is why the same technology gives a different payback calculation depending on equipment size.

Same technology, different math

The benefit scales with equipment size, but the build cost does not

Large continuous processes
Mid-sized and small processes
Value of a 1% improvement
Very large
Relatively small
Build cost
Recoverable
Long payback period
Dedicated control staff
Yes
Mostly none
Process characteristics
Continuous, stable
Often batch, irregular

Processes with nonlinear responses carry an even heavier burden. In the same survey, nonlinear MPC applications numbered 93, about 2% of linear ones, and the authors note that an empirical nonlinear model requires even more test data than a linear one. A neutralization tank, where the size of the pH change varies greatly with the dosing, is such a process.

The questions practitioners raise point in the same direction. The research needs that Qin et al. compiled from industry were engineering problems rather than algorithmic ones, such as "When is a model good enough to stop the plant test?" and "How do you estimate the benefits of a control system?"

Filling the gap

There are approaches that, instead of testing, learn how the process responds from operating data that has already accumulated. One nonlinear MPC product described by Qin et al. learned the steady-state relationship from historical operating data and used plant testing only for the dynamic part, on the view that historical data contain rich steady-state information. The authors judged that closed-loop identification, which updates the model with data collected during operation, would be useful but was rarely practiced at the time.

Operating data have limitations too. A plant test forbids coordinated moves between variables, but routine operating records have no such restriction, so periods where several variables moved together can be mixed in. That makes it hard to separate the effect of each variable. This direction could be called "the democratization of APC," but there are hurdles to clear before it is used on the floor.

What data-driven prescription has to overcome

Lowering cost alone is not enough

Data qualitySetpoints and results must be recorded together
Without a record of adjustments, it cannot learn the responses
SafetyDo not step outside the data
Conditions it has not experienced are not prescribed
ExecutionPrescriptions must actually be executed
From on-screen guidance to application on the equipment

What APC has proven is that "companies pay for process optimization." The remaining question is how to deliver the same value at lower cost, to many more plants.

References

Could this work for your process?

Talk to us