Scenarios
Steel & Specialty Steel · Maintenance · Anomaly responseExample scenario
Operating Conditions on Anomaly Signs
Failure prediction says when a machine may fail, not how to run it until maintenance. Wrong conditions mean lost output or an unplanned stop.
−38%Unplanned downtime
+6%Overall equipment effectiveness (OEE)
Example scenario. Figures are illustrative.


Plant dataGearbox vibration7.8 mm/s
PrescriptionSpindle speed before repair1,800 → 1,500 rpm
PrescriptionLoad before repair100 → 80%
Expected resultUnplanned downtime40 → 25 h/mo
Plant dataPrescriptionExpected result
On the floor
- Situation
- During a production peak for a large order, a key machine starts showing rising vibration.
- Trade-off
- Cutting load sharply misses this week's output target; running as is risks a breakdown that stops the whole line.
- Limit
- No procedure weighs failure risk against lost output for each operating condition, so each case is handled ad hoc.
01
02
03
How we solve it
Learns how operating conditions affect failure risk and lost output from sensor history, failure records and production results, then calculates the lowest-loss speed and load within safety rules.
Plant data
- Vibration & temperature sensors
- Spare parts stock
- Maintenance crew status
- Remaining orders
Prescription
- Spindle speed until maintenance1,800 rpm → 1,500 rpm
- Equipment load until maintenance100% → 80%
- Lubricant supply1.2 L/h → 1.6 L/h
Also adjustedCooling water flow
Constraints
- Mandatory safety inspection intervals
- Immediate stop above vibration alarm limit
Expected results
Unplanned downtime−38%
40 h/mo→25 h/mo
BeforeExpected
Overall equipment effectiveness (OEE)+6%
72%→76.3%
BeforeExpected
Could this work for your process?
Tell us about your process and data, and we will assess feasibility.
Scenarios

Steel & Specialty Steel
Leaching/Neutralization
Example scenarioLeaching/Neutralization
pH Control in Leaching & Neutralization
Prescribes caustic soda dosing to hold pH on target and raise nickel recovery.
+4.8%
Nickel recovery
−62%
Time out of pH range
−9%
Caustic soda usage
Caustic soda dosing 12.0 L/h → 13.4 L/h

Steel & Specialty Steel
Electric Arc Furnace
Example scenarioElectric Arc Furnace
EAF Flux Addition
Prescribes lime addition to hit tapping temperature and cut power use.
+12%p
Tapping temp. hit rate
−3.1%
Power intensity
−8%
Lime consumption
Voltage tap 6 → 5

Steel & Specialty Steel
Open-Die Press
Example scenarioOpen-Die Press
Forging Pass Reduction Schedule
Prescribes reduction per pass and rotation angle to cut reheating cycles.
−1
Reheats
−9%
Forging cycle time
Reduction per pass 45 mm → 38 mm